Coupling Model for Temperature/Stress Fields Analysis in Slab Casting Moulds
-
Graphical Abstract
-
Abstract
Considering the effect of water slots in the cooling side of copper and the mould taper on the temperature field and stress field of the slab, the coupling thermal and stress FEM model for the continuous mould was presented. The coupling model can reveal the temperature field of the slab and the thermal mechanical deformation of the copper. All the results accord with the fact.
-
-